Single Element Detector

                                                       Pixel Size = 100 μm x 100 μm

Dark Current vs. Bias Voltage

 

 

 

 

 

 

Responsivity vs. Wavelength

 

 

                                                                                                                  T=40K                                                                T=77K

 

                                                                             T=163K                                                                    T=205K

 

 

 

 

 

 

 

 

Summary of Test Results of Design 1

 

T(K)

Bias (V)

 

λρ (μm)

Rip (A/W)

(peak responsitivity)

D*(cm-Hz 1/2/W)

(Detectivity)

40K

-3.5

3.4

0.247

1.51E11(BLIP)

 

-3.0

3.4

0.207

1.38E11(BLIP)

 

-2.5

3.4

0.16

1.21E11(BLIP)

 

0

3.4

0.024

0.47E11(BLIP)

77K

-3.5

3.4

0.186

0.55E10

 

-3.0

3.4

0.159

0.54E11(Non-BLIP)

 

-2.5

3.4

0.123

0.73E11(BLIP)

 

0

3.4

0.019

0.89E11(BLIP)

150K

-3.0

3.4

0.134

0.17E10

 

-2.0

3.4

0.086

0.16E11

 

-1.0

3.4

0.037

0.71E11(Non-BLIP)

 

0

3.4

0.037

0.37E11(BLIP)

163K

-3.0

3.4

0.132

0.136E10

 

-2.0

3.4

0.095

0.64E10

 

-1.0

3.4

0.053

0.15E11(Non-BLIP)

 

0

3.4

0.013

0.34E11(BLIP)

205K

-1.5

3.4

0.11

0.18E10

 

-1.0

3.4

0.088

0.21E10

 

-.0.5

3.4

 

0.17E10(Non-BLIP)

 

0

3.4

0.009

0.46E9(Non-BLIP)